Light Scattering

DLS-1

brand: ALV

Description: 300 mW 660 nm DPSS laser APD Detector ALV Correlator

Use for: DLS, depolarised DLS and SLS. Due to high wavelength suitable for fluorescent particles and quantum dots. Temperature range 10 - 60 C

room: 6101, Helix

Literature Specs: ALV-125 goniometer, ALV5000/60X0 External correlator, ALV / HIGH QE APD Single Detector with Static and Dynamic Enhancer Fiber optics, Cobolt Flamenco 300mw DPSS laser @ 660 nm, Haake F8-C35 Thermostated Bath

DLS1.jpg

DLS-2

brand: ALV

Description: 300 mW 532 nm DPSS laser Photomultiplier Detector ALV Correlator

Use for: DLS, depolarised DLS and SLS. Automatic temperature scans possible. Temperature range 10 - 80 C

room: 6101, Helix

Literature Specs: ALV-SP/86 goniometer, ALV7002 External correlator, Thorn RFIB263KF PMT, ALV 50/100/200/400/600 μm Pinhole detection system, Cobolt Samba 300mw DPSS laser @ 660 nm, Haake Phoenix-II / C30P Thermostated Bath

DLS2.jpg

DLS-3

brand: home-build

Description: 300 mW 532 nm DPSS laser Photomultiplier Detector ALV Correlator

Use for: DLS at fixed angle (90 degrees) Automatic temperature scans possible. Temperature range 10 - 80 C

room: 6101, Helix

Literature Specs: Homebuild, ALV7002-USB correlator, ALV/SO SIPD Single Photon Detector, ALV Static and Dynamic Enhancer Fiber optics, Cobolt Samba 300 mW DPSS laser @ 532 nm, Julabo CF41 Thermostated Bath

DLS3.jpg

DLS-5

brand: ALV

Description: 22 mW 632.8 nm Laser Dual APD Detector

Use for: DLS, depolarised DLS and SLS. Due to high wavelength suitable for fluorescent particles and quantum dots. Temperature range 10 - 40 C Rotation unit for non-ergodic samples

room: 6101, Helix

Literature Specs: ALV/LSE-5004 goniometer, ALV7004 External correlator, ALV / Dual High QE APD Detector Unit with fibre splitting device, Uniphase 1145P HeNE 22 mW laser @ 632.8 nm, Julabo CF41 Thermostated Bath

DLS5.jpg

Titrator-DLS

type (brand): T200 (Schott)

Description: Can be combined with DLS-1, DLS-2, DLS-3 and DLS-5

Use for: Titrations can be done in the DLS cuvet, after each addition a set of DLS runs can be performed automatically

room: 6101, Helix

Literature Specs: Schott Titronic T200 Buret with TA05 Exchange Unit

DLS / ZetaSizer

type (brand): ZS-Nano (Malvern)

Description: 632.8 nm HeNe laser and APD Detector

Use for: DLS Measurements at 13 or 173 degrees detector angle. Temperature scans possible. Small volume cuvette available (35ul). Possibility to determine the zeta potential of charged particles

room: 6083, Helix

Literature Specs: Malvern NanoSizer Zeta

ZSNanoMalvern.jpeg